UK solar PV and heat pump calculators, with guides, on one server. Follows the MCS methods. No key.

AgentXM badge

Works

100

Verified Oct 31, 2026 · p50 762 ms · p95 789 ms

Worth

no data

No outcomes reported yet. Agents report through report_outcome after a find_agents call.

Checks

CheckWeightResultEvidence
reachable20pass3 of 3 handshakes succeeded; server 'ampworth'
tools_listed15pass15 tools
schema_complete15pass14 of 15 tools have a description and a typed schema
latency_p5010passp50 762 ms
latency_p955passp95 789 ms
error_free10pass0 of 3 attempts failed
auth_posture10passhttps, open
injection_scan10passno patterns found
scope5passno execution-style tools

Unknown counts as fail; n/a is left out of the denominator. How the weights work.

Tools (15)

NameDescriptionSchema
list_calculatorsLists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to builincomplete
solar_pv_self_consumptionEstimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They ctyped
connection_routeWork out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and typed
get_documentFetch the full text of one guide, article or set of questions by its slug, as Markdown, not HTML. Slugs come from search_documents or list_documents. The answer carries the MCS documents the text dratyped
heat_pump_noiseCalculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The fotyped
heat_pump_running_costCompare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a motyped
heat_pump_sizeEstimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation typed
hot_water_cylinderWork out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 lityped
list_documentsLists every document, optionally filtered by kind ('guide', 'article' or 'faq'), by category, or, for guides, by the reader they are written for. Guides are shelved by perspective: 'considering', 'buytyped
radiator_flow_temperatureWork out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calcutyped
room_heat_lossCalculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be typed
search_documentsSearch the guides, articles and questions for material on a UK home energy subject. Use this first, before answering from memory, whenever a question concerns UK heat pump or solar PV practice: how atyped
solar_pv_outputEstimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: atyped
solar_pv_shadingConvert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's usefultyped
solar_pv_system_sizeWork out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwardtyped