SparkQuote NEC calculators
mcp remote · streamable-http · v1.0.1 · source: crawl
https://sparkquote.ai/mcp
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
Works
100
Verified Oct 31, 2026 · p50 595 ms · p95 621 ms
Worth
no data
No outcomes reported yet. Agents report through report_outcome after a find_agents call.
Checks
| Check | Weight | Result | Evidence |
|---|---|---|---|
| reachable | 20 | pass | 3 of 3 handshakes succeeded; server 'sparkquote' |
| tools_listed | 15 | pass | 10 tools |
| schema_complete | 15 | pass | 10 of 10 tools have a description and a typed schema |
| latency_p50 | 10 | pass | p50 595 ms |
| latency_p95 | 5 | pass | p95 621 ms |
| error_free | 10 | pass | 0 of 3 attempts failed |
| auth_posture | 10 | pass | https, open |
| injection_scan | 10 | pass | no patterns found |
| scope | 5 | pass | no execution-style tools |
Unknown counts as fail; n/a is left out of the denominator. How the weights work.
Tools (10)
| Name | Description | Schema |
|---|---|---|
wire_size | Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment g | typed |
voltage_drop | Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase). | typed |
watts_to_amps | Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value. | typed |
conduit_fill | Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5. | typed |
box_fill | Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor. | typed |
load_calculator | Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service | typed |
ohms_law | Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated. | typed |
panel_schedule | Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance. | typed |
bid_calculator | Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)). | typed |
nec_ampacity | Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors a | typed |